Description

Reduce your energy costs and increase your efficiency with the VD 500. Suitable directly for measurement after the compressor. Monitor the delivery rate of your compressor and create a FAD analysis.

  • Measurement immediately downstream of the compressor
  • Measurement at high temperatures
  • New: Unique sensitivity in the lower measuring range: Measures from as little as 2 m/s and thus covers the complete operating range of variable speed drive (VSD) compressors
  • Particularly suitable for extremely high flow rates
  • Flow, total consumption, temperature and pressure
  • Measurement at high temperatures, max. temperature 180 °C
  • Can be used in pipes from DN 20 to DN 600
  • Installation via 1/2″ ball valve under pressure
  • Measurement of the capacity of compressors
  • Compressed air audits
  • Efficiency measurement of compressed air systems
  • After functioning water separator
  • In horizontal lines (recommended) or in risers
  • 04…20 mA, pulse and a Modbus RTU (RS 485) interface as standard
  • Optional interfaces like Modbus TCP (Ethernet), PoE, M-Bus
  • Pressure range up to 30 bar
  • Temperature of the medium -30 ° … +180 °C
  • Integrated display to show the measured values
  • Available from DN20 to DN500
  • Easy installation under pressure
  • Settings adjustable via the keys of the display
  • Main counter reading can be reset via the display
  • Can be used for velocities up to 600 Nm/s
  • High accuracy with 1.5% deviation of the measured value